Search results for " filtered"
showing 10 items of 19 documents
Probing Physical Properties of Confined Fluids within Individual Nanobubbles
2008
Spatially resolved electron energy-loss spectroscopy (EELS) in a scanning transmission electron microscope (STEM) has been used to investigate as fluidic phase in nanoubbles embedded in a metallic Pd90Pt10 matrix. Using the 1s->2p excitation of the He atoms, maps of the He distribution, in particular of its density an pressure in bubbles of different diameter have been realized, thus providing an indication of the involved bubble formation mechanism. However, the short-range Pauli repulsion mechanism between electrons on neighboring atoms seems insufficient to interpret minute variations of the local local measurements performed at the interface between the metal and the He bubble. Simul…
A Scanning Electron Microscope for Ultracold Atoms
2006
We propose a new technique for the detection of single atoms in ultracold quantum gases. The technique is based on scanning electron microscopy and employs the electron impact ionization of trapped atoms with a focussed electron probe. Subsequent detection of the resulting ions allows for the reconstruction of the atoms position. This technique is expected to achieve a much better spatial resolution compared to any optical detection method. In combination with the sensitivity to single atoms, it makes new in situ measurements of atomic correlations possible. The detection principle is also well suited for the addressing of individual sites in optical lattices.
1996
The uses of atomic force microscopy, scanning tunneling microscopy, electron spectroscopic imaging, electron energy loss spectroscopy and low voltage, high resolution scanning electron microscopy in polymer research are reviewed
On the 1-handles of the product V3XBn for a simply connected open 3-manifold V3
2013
Although \pi_1^\inftyV^3 is an obstruction for killing stably the 1-handles of an open simply connected 3-manifold V^3, one can always get rid of the 1-handles of V^3\times B^n, for high enough n, at price of a certain nonmetrizable slackening of the topology.
Automated diffraction tomography combined with electron precession: a new tool forab initionanostructure analysis
2009
AbstractThree-dimensional electron diffraction data was collected with our recently developed module for automated diffraction tomography and used to solve inorganic as well as organic crystal structuresab initio. The diffraction data, which covers nearly the full relevant reciprocal space, was collected in the standard nano electron diffraction mode as well as in combination with the precession technique and was subsequently processed with a newly developed automated diffraction analysis and processing software package. Non-precessed data turned out to be sufficient forab initiostructure solution by direct methods for simple crystal structures only, while precessed data allowed structure s…
Structure analysis of titanate nanorods by automated electron diffraction tomography
2011
A hitherto unknown phase of sodium titanate, NaTi3O6(OH)·2H2O, was identified as the intermediate species in the synthesis of TiO2 nanorods. This new phase, prepared as nanorods, was investigated by electron diffraction, X-ray powder diffraction, thermogravimetric analysis and high-resolution transmission electron microscopy. The structure was determined ab initio using electron diffraction data collected by the recently developed automated diffraction tomography technique. NaTi3O6(OH)·2H2O crystallizes in the monoclinic space group C2/m. Corrugated layers of corner- and edge-sharing distorted TiO6 octahedra are intercalated with Na+ and water of crystallization. The nanorods are typically …
Bootstrap validation of links of a minimum spanning tree
2018
We describe two different bootstrap methods applied to the detection of a minimum spanning tree obtained from a set of multivariate variables. We show that two different bootstrap procedures provide partly distinct information that can be highly informative about the investigated complex system. Our case study, based on the investigation of daily returns of a portfolio of stocks traded in the US equity markets, shows the degree of robustness and completeness of the information extracted with popular information filtering methods such as the minimum spanning tree and the planar maximally filtered graph. The first method performs a "row bootstrap" whereas the second method performs a "pair bo…
Coronary CT angiography using iterative reconstruction vs. filtered back projection: evaluation of image quality.
2014
To compare image quality of iterative reconstruction algorithm(IRIS) vs. standard filtered back projection(FBP) reconstruction in CT Coronary Angiography (CTCA).Thirty-four consecutive patients underwent CTCA for suspected or known CAD with Dual-Source CT (DSCT-Flash, Siemens). All datasets were reconstructed with 0.75/0.4 and 0.6/0.4 mm slice thickness/increment, using three standard FBP kernels (B26-B30-B46) and three comparable IRIS algorithms (I26-I30-I46). Vascular attenuation and noise were measured. CT vascular attenuation values [HU] were measured in: ascending aorta (Ao), right (RCA) and left (LCA) coronary artery, respectively. Signal-to-noise (SNR) and contrast-to-noise (CNR) rat…
Second-harmonic Generation Microscopy of Carbon Nanotubes
2012
We image an individual single-walled carbon nanotube (SWNT) by second-harmonic generation (SHG) and transmission electron microscopy and propose that SHG microscopy could be used to probe the handedness of chiral SWNTs.
Structural Characterization of Organics Using Manual and Automated Electron Diffraction
2010
In the last decade the importance of transmission electron microscopic studies has become increasingly important with respect to the characterization of organic materials, ranging from small organic molecules to polymers and biological macromolecules. This review will focus on the use of transmission electron microscope to perform electron crystallography experiments, detailing the approaches in acquiring electron crystallographic data. The traditional selected area approach and the recently developed method of automated diffraction tomography (ADT) will be discussed with special attention paid to the handling of electron beam sensitive organic materials.